Green Good Design Awards Tell a friend

Green Good Design Awards ARCHIVE 2021 Green Research/Technology
LinkedIn Middlefield Campus Carbon Action Plan | 2020
BACK TO ARCHIVE
LinkedIn Middlefield Campus Carbon Action Plan | 2020

Mountain View, California, USA

Architects: Adrian Smith + Gordon Gill Architecture, Chicago, Illinois, USA

The practice was engaged by LinkedIn in March 2020 to prepare a Carbon Action Plan (CAP) for their Middlefield Campus in Mountain View, California. At the beginning of 2020, LinkedIn and its parent company, Microsoft, announced their intent to become carbon neutral in embodied and operational carbon emissions by 2030.

They have currently put the design of their global headquarters on hold while the team studies existing designs and makes recommendations on an approach to delivering a carbon-positive campus. The CAP includes multiple Lifecycle Analyses, detailed materials research, structural options, design efficiency studies, operational energy reduction strategies, sitewide strategies, and a comprehensive set of technology scenario plans and final recommendations.

The CAP will be used to inform design decisions for LinkedIn’s built assets globally. The project is particularly innovative in its level of integration. Client, architects, structural engineer, main contractor, and ready-mix concrete supplier all working together to establish a road map for low carbon concrete construction. Through developing and testing strategies that will reduce carbon emissions, this report and Carbon Action Plan (CAP) becomes a reference document that can be used for future LinkedIn projects nationally and internationally.

Through the analysis of several different scenarios, the team recommended in this report a range of alternative, lower carbon building solutions and materials selections covering all building stages from design to fit out.

The plan is divided into three main chapters:

Chapter 1 introduces the project and major project goals.

Chapter 2 reviews the existing building design for the proposed buildings. Since these buildings were placed on hold when the projects were already significantly through the design phases, existing detailed documentation was used to prepare a baseline whole building Lifecycle Analysis (LCA).

In Chapter 3, the CAP studies and presents material and design recommendations. This chapter recommends a design process in which all necessary stakeholders are involved early within the design process, providing critical industry and market feedback, which should inform early-stage design decisions.

The process should include performance-based analyses and simulations for both embodied and operational carbon, all of which are related back to lifecycle carbon performance. A final chapter explores an approach to writing specifications that will ensure that the strategies identified during design are implemented during construction. The chapter also includes an evaluation of existing green building certifications and their requirements relating to embodied carbon reductions.

The CAP acknowledges the importance of a building’s floor plate efficiency as it relates to carbon. Therefore, it is proposed that during design, the carbon footprint is measured using the metric of embodied carbon per sqm of usable space, where embodied carbon is the total embodied carbon of the whole building. This metric represents a new and important shift in tracking the carbon impact of structural and floor plate efficiency strategies, in addition to the many proposed material strategies.

All major components of the building have been evaluated, and a series of potential alternatives for embodied carbon reduction is proposed. Implementing a variety of material improvements, described as Intervention Level 1, the existing steel building is optimized to understand the lowest embodied carbon achievable by the existing design. Additionally, as Intervention Level 2 proposals, alternate structural systems are evaluated, and their lifecycle carbon emissions calculated.

The Parking Garage is also evaluated as part of Chapter 4, where in addition to material choices, the team also looks at strategies that allow it to be designed to be repurposed as the need for parking decreases over time.

Office Building Recommendation

The company recommends that CON02BP (with 100% BPA utilization) be the preferred solution. This option delivers a building that is 442 tons carbon negative. They believe that this number could be further increased (made even more negative) by implementing the additional carbon reduction recommendations proposed in the report.

Should the Blue Planet Aggregate not be achievable due to schedule, the secondary recommendation would be CON02. This option delivers a 56% reduction in embodied carbon over the steel baseline. Without either using materials that sequester carbon or purchasing offsets, it is not possible to achieve carbon neutrality.

However, like CON02BP, these options promote a high degree of innovation and will result in a significantly lower total carbon footprint.

Parking Garage P2 Recommendation

In a post-Covid, social distancing aware environment, it is likely that LinkedIn’s real estate development strategy will be reviewed. The assumption being that more staff will want to work from home regularly, and that space requirements will change.

Coupled with a heightened awareness of how, during the Covid-19 pandemic, transportation emissions have fallen, and air quality has improved, there is likely to be added stimulus and incentive for moving away from business as usual commuting to work by car.

The parking garage provides a unique opportunity to be particularly creative: to create a carbon battery for the campus. It is likely that in the short-term LinkedIn will need the floor space provided in B6 and that Parking P2 will also be required.

The team’s recommendation, based on a prediction that parking demand will decrease in the future due to reduced ownership as well as autonomous cars replacing driver operated cars, is to build a concrete parking garage that is designed in such a way that it can easily be converted into either residential, hotel or office space.

If the garage is built using 100% BPA in the ready-mix concrete and 50% BPA in the pre-cast elements, the building is significantly carbon-negative – 911 tons. Combined with the fact that it has a significant roof area that could be covered with PV, the building can be used as a carbon bank for the rest of the site.

Further reductions in embodied carbon are possible, and the teamrecommends: Exploring the same improvements as B6; Considering fiber reinforcement of pre-cast elements; Considering Geopolymer cement such as Solidia or e-Crete in the pre-cast elements.