Green Good Design Awards Tell a friend
Architects: Robert A. M. Stern Architects, New York, New York, USA
Client: Kohler Company, Kohler, Wisconsin, USA
Client: Choate Rosemary Hall, Wallingford, Connecticut, USA
Construction Manager: Shawmut Design and Construction, Boston,
Massachusetts, USA
Structural Engineers: DeStefano & Chamberlain, Inc., Wallingford, Connecticut, USA
Mechanical/Electrical/Plumbing/Fire Protection Engineers: Kohler Ronan, LLC., Danbury, Connecticut, USA
Sustainability Consultants and Lighting Designers: Atelier Ten, New York, New York, USA and New Haven, Connecticut, USA
Greenhouse Consultants: Agritechnove Inc., St. Anselme, Quebec, Canada
Photographers: Peter Aaron, ESTO Photographics
Project Description
Some schools build environmentally responsible buildings; some schools teach environmental responsibility. The Kohler Environmental Center, a laboratory for living and learning at Choate Rosemary Hall, brings these two objectives together. Set in the midst of 268 acres of meadows, agricultural fields, second-growth forest, and wetlands, the Kohler Center allows students to learn from the site's exceptional biodiversity and range of habitats. The Center is approached by a footpath over a wooded wetland ravine that leads to a central, south-facing courtyard. A cloister lining the courtyard links the Kohler Center's 14 dormitory rooms, faculty apartments, common spaces, classrooms, laboratories, and a state-of-the-art research greenhouse. The building's materials reflect its rustic setting—native stone walls, stained cedar trim, and fiber-cemented plank siding.
The new LEED Platinum Kohler Environmental Center was designed to achieve net-zero energy usage with the goal of teaching environmental stewardship through sustainable design of the building itself. 100% of the 31,325-square-foot building's annual energy needs is provided by a 294-kilowatt photovoltaic array, roof-mounted thermal solar panels, and waste cooking oil. The Center’s building shell is designed to minimize heat loss in the winter and heat gain in the summer, and in turn reduce the energy required for space conditioning. Structural insulated panels at the roof combined with thick staggered double-stud exterior walls filled with spray insulation provide more than double the insulating value of typical construction and minimize thermal bridging to the exterior. Deep eaves and south-facing sunshades filter solar heat gain in the summer and allow it in the winter.
The largest energy demand from most buildings comes from heating and cooling. The Kohler Environmental Center’s 800-foot-long earth duct, buried ten feet below ground, capitalizes on the soil’s constant temperature of 55˚F to precondition fresh air for the building’s HVAC system. In the winter, cold air is warmed by the ground before being heated by the building’s mechanical system causing it to “work less,” and vice versa in the summer. The earth duct, in addition to 25 geothermal wells, reduces the building’s energy demand for space conditioning by 24%. The natural ventilation strategies employed at the Kohler Environmental Center minimize the need for mechanical cooling. Operable windows in all spaces allow users to control thermal comfort as needed. The tower acts as a solar chimney, using convection to enhance the natural stack effect of hot air to exit the building at a high point while drawing cooler air into the building at low points. The classrooms and public spaces use a similar technique with operable windows on opposing sides of the room, one high and one low, enhancing natural cross ventilation. Tall and clerestory windows provide natural daylight to the majority of the KEC’s occupied spaces, minimizing the need for artificial lighting.
The Kohler Environmental Center’s roof-mounted evacuated solar hot water tubes can heat 160,000 gallons of water annually, supplying 100% of the Center’s anticipated hot water needs. The greenhouse adjacent to the center is heated by a boiler that uses waste cooking oil from Choate's kitchens. Rainwater is collected in a cistern attached to the greenhouse to water the experimental gardens inside. Additionally, bathrooms are equipped with low-flow Kohler plumbing fixtures to conserve water.
All of the species of landscape selected at the KEC are native plants and grasses, and were selected for their beauty, which will attract native birds and insects and require little maintenance to sustain them. Mowing will take place sporadically and only to prevent the growth of invasive species. The grasses will grow to a maximum of three feet tall and were selected so that they will not block any sunlight from hitting the PV array.