Green Good Design Awards Tell a friend

Green Good Design Awards ARCHIVE 2014 Green Architecture
BAD AIBLING CITY HALL, 2009-2012 - Bad Aibling, Germany
  • BAD AIBLING CITY HALL, 2009-2012 - Bad Aibling, Germany
  • BAD AIBLING CITY HALL, 2009-2012 - Bad Aibling, Germany
  • BAD AIBLING CITY HALL, 2009-2012 - Bad Aibling, Germany
BACK TO ARCHIVE
BAD AIBLING CITY HALL, 2009-2012 - Bad Aibling, Germany

Architects: Behnisch Architekten, Stuttgart, Germany
Client: Statdt Bad Aibling, Bad Aibling, Germany 
Photographers: David Matthiesen

Project Description

In the center of the Bavarian town of Bad Aibling lies Marienplatz, a historic plaza flanked by public, retail and hotel buildings. It is here that the two main streets of the town intersect and where the existing Town Hall from the 1970s has stood. In recent years, the town of Bad Aibling decided to construct a new Town Hall as a means by which to further invigorate the center.

The old town hall was demolished down to the cellar level. Keeping the cellar and the building foundations intact was part of the client’s brief for the project, and therefore a key constraint in planning. The new building has been erected on the foundations of the existing Hall, respecting the pre-determined load-bearing capacity of the cellar and foundations as well as the existing supply network. The planning team chose a lightweight construction for this reason that consisted of a concrete skeletal structure with wood-clad walls.

The new hall accommodates primarily public functions. It is designed as a multi-functional venue that houses a variety of programs – including space for citizens’ services, administrative offices, meeting rooms, as well as a public library and a registry for weddings - all under one roof. 

In addition, part of the project brief was to vitalize the ground floor level of the city center. This was accomplished through the integration of retail program at ground level, consisting of shops and a café. Their presence here has transformed this public space into an environment that is lively and engaging both during and after business hours.

The entrance of the town hall from Marienplatz leads into an atrium that hovers above the stories. From here, visitors can circumnavigate the building and experience it as a truly public space - a flowing, communicative public thoroughfare for casual and planned encounters.

The Bad Aibling City Hall is a pioneering project in terms of sustainability and ecology. Due to the holistic design approach pursued, the building is not only energy efficient, but also serves the social dimensions of enhancing integration and communication for its users, as well as ensuring long-term use through its programmatic and spatial flexibility. In addition to this, the structure utilizes the existing foundations and cellar of the former town hall from 1970. From the very onset of the project, the design concept focused on a holistic approach to energy use. The compact form of the building, its high-performance insulation, triple-glazing, external blinds and mechanical ventilation with waste heat recovery provide the best basis for an energy efficient building. The energy concept also includes the implementation of LED-lighting throughout.

A particular emphasis is placed on the supply of heating and cooling. Therefore three goals were set at the outset of the project: - The primary energy factor for heating, cooling, ventilation and lighting should undercut the current German regulations on energy saving (EnEV 2009) by 50 %. - The equivalent CO2-emission should be lower than the conventional reference system (a natural gas boiler). - The heating and cooling supply should be operated economically. The building is heated through the use wood pellets, the source of energy with the lowest primary energy factor and the lowest amount of CO2-emissions. The particulate emission of the wood pellet boiler lies at a very low 3 mg/Nm•, undercutting by far the second phase of the Federal Pollution Control Act (BImSchG) that will go into effect in 2015, requiring 20 mg/Nm•. The cooling operates through the use of water from a nearby creek. It is used for the component activation of the ceiling, the mechanical ventilation and the convection cooling of the server rooms.

NEXT/PREVIOUS
METROPOLITAN ARTS PRESS