Designers: Senzer Limited, London, United Kingdom
Manufacturer: Senzer Limited, London, United Kingdom
The new industry standard: revolutionising the delivery of systematic medications through the lungs
A unique and proven drug delivery platform currently in production for the US regulated market with delivery planned for Q3 2018. Patient friendly and easy to use, the breath operated inhaler is underpinned by over 330 granted patents and design rights worldwide. A next generation technology to deliver fast acting, effective and reliable treatments.
As the bespoke shaped refill end of the inhaler is inserted into the all-in-one Refill Pack it is charged with a single dose of the drug. Finely tuned springs ensure the inhaler reservoir valve opens before the drug canister valve, creating a tight seal during filling and preventing the loss of any drug formulation.
1. Charge
After charging, the user attains the single dose by sucking air effortlessly through the inhaler over 3 to 5 gentle breaths. The dose will only be released when the users inspiratory flow rate is sufficient to trigger the valve resulting in a delivery that is customised to a patients respiratory ability.
2. Inhale
The SiDDTM inhaler is designed with the user in mind: it’s simple to use, compact and attractively designed.
Patients will feel both comforted by its presence in their pocket and confident to use it in public. The profiled green mouthpiece visually communicates what part of the device the user should inhale from and creates an effective seal between their lips and the inhaler. The ergonomic contoured shape makes charging the inhaler easy and instinctively tells the user how to hold the device.
The Technology
The key feature that differentiates the SiDDTM inhaler is its unique breath operated valve technology. The inhaler is activated by the user generating a pressure differential between the Upper and Lower Air Chambers within the inhaler as they breathe through it. Air is drawn through side inlets into the Upper Air Chamber and out through the mouthpiece outlets. The resultant pressure drop within the Lower Air Chamber causes the Vane & Diaphragm between the two chambers to rotate down, the Vane Tooth to lift, and the pressurised formulation to be released from the Internal Reservoir. Drug formulation passes through the Sealing Tube before it joins the air being drawn into the patients lungs. The precise profile of the Sealing Tube creates turbulent flow, aerosolization and formulation with optimal characteristics for effective drug delivery. This finely tuned system results in drug particles of the ideal size being delivered at the optimal time directly into the laminar flow being drawn into the users lungs.